Serial Communication Kit
TM/TMC-4200CL Series Progressive Scan Cameras
TABLE 8.
TM-4200CL Command Response Table
Command
Parameter
End of 
Cmd
Ack. Response
Description
:SGE=
X
<cr>
:o<cr>
Set Digital Output Interface 
(X = 0 CameraLink, X = 1 GigE)
:CCD=
X
<cr>
:o<cr>
CCD information (X = 1)
:PuLX
X
<cr>
:o<cr>
Password (X = 1 Administrator, X 
= 0 Users)
Note: If a command is not accepted for any reason, the camera will return a “nack” 
response. “:e” <cr> *Not available yet.
Command
Parameter
End of Cmd
Description
Byte 1, 2
Master Gain
Master Gain (H'0000 - H'0FFF: -3dB - +12dB) 
Byte 3, 4
R Channel Fine 
Gain
R Channel Fine Gain (H'0000 - H'0FFF)
Byte 5, 6 
Master Offset
Master Offset (H'0000 - H'0FFF)
Byte 7, 8
R Channel Fine 
Offset
R Channel Fine Offset (H'0000 - H'0FFF)
Byte 9
Function Flag 0
Bit 0
Scan Area 0
0000=2048x2048    0001=2048x1000    
0010=2048x500    0011=2048x250
Bit 1
Scan Area 1
0100=2x2 binning of 2048x2048     1111=User 
Programmable Scan Area
Bit 2
Scan Area 2 
1000=Digital Zoom x1     1001=Digital Zoom x2
Bit 3
Scan Area 3
1000=Digital Zoom x3     1001=Digital Zoom x4
Bit 4
Rsvd
Bit 5
Rsvd
Bit 6
Pixel Output 
Order 0
00=<---<---    01<=<------>
Bit 7
Pixel Output 
Order 1
10=<<------
Byte 10
Function Flag 1
Bit 0
Shutter 0
Continuous Mode: 0000 - 1001=Continuous pre-
set shutter 0 - 9