Page 140
RESULTS:
If  sparking  still  does  not  occur  after  adjusting  the 
armature  air  gap,  testing  the  ground  wires  and 
performing  the  basic  flywheel  test,  replace  the 
ignition magneto(s).
PROCEDURE, REPLACING MAGNETOS:
1.  Follow all steps of the Major Disassembly procedures 
that are located in Section 6.
2.  Once the magnetos are visible, make note to how 
they are connected.
note:  each  magneto  has  its  own  part  number. 
Verify the part number prior to installation.
3.  Cylinder  one  is  the  back  cylinder  (Figure  36)  and 
cylinder two is the front cylinder (Figure 37).
Figure 36. Cylinder One (Back, Short)
Figure 37. Cylinder Two (Front, Long)
4.  When  installing  new  magnetos  there  will  be  one 
with  a  short  plug  wire  and  one  with  a  longer  plug 
wire (Figure 38).
Figure 38.
note:  magneto  gap  between  flywheel  needs  to 
be 0.010 inch.
5.  Long plug wire (B) will be installed on front cylinder 
number two.
6.  Short plug Wire (A) will be installed on back cylinder 
number one.
7.  Verify installation of magnetos correctly by ensuring both 
spark plug wires point to the back of the enclosure and 
shutdown terminals are nearest cylinder head as shown 
in Figures 39 and 40.
Figure 39.
Figure 40.