Siemens TC12 사용자 설명서

다운로드
페이지 201
 
TC12 Installation, Commissioning & Maintenance Handbook 
The following table shows the TCSU default configuration values: 
 
Table 7 - TCSU default configuration values 
 
SUMMARY OF DEFAULT CONFIGURATION DATA CHANGES FOR TCSU TC12 OTU 
 
Handset Item 
Standard 
TCSU 
TCSU Default Comments 
GNO 
Maximum number of OTUs per Instation 
modem.  
GRW0 
→ GRW5  4 
Number of Reply words for each OTU 
GSA0 
→ GSA11  No SCOOT  GSA0 = 16 
SCOOT LOOP- input allocation: 
 
loops 
GSA1 = 17 
8 loops allocated to input port 2 -  
 
allocated 
GSA2 = 18 
inputs 16 to 23. 
 
(255) 
GSA3 = 19 
 
 
 
GSA4 = 20 
 
 
 
GSA5 = 21 
 
 
 
GSA6 = 22 
 
 
 
GSA7 = 23 
 
GRL2 0 etc 
From OTU 
GRL2 0 =21  Reply bit function: 
 
input (0) 
GRL2 4 =22  Reply words 2, 3, 4, 5 allocated to 8  
 
 
GRL3 0 =23  SCOOT nibbles. 
 
 
GRL3 4 =24   
 
 
GRL4 0 =25  Reply words 0,1 default to OTU 
 
 
GRL4 4 =26  inputs to provide 16 traffic controller 
 
 
GRL5 0 =27  reply bits. 
 
 
GRL5 4 =28   
 
666/HE/43100/000  
Page 129 
Issue 9