The following table shows the TCSU default configuration values:
Table 7 - TCSU default configuration values
SUMMARY OF DEFAULT CONFIGURATION DATA CHANGES FOR TCSU TC12 OTU
Handset Item
Handset Item
Standard
TCSU
TCSU Default Comments
GNO
1
6
Maximum number of OTUs per Instation
modem.
modem.
GRW0
→ GRW5 4
6
Number of Reply words for each OTU
GSA0
→ GSA11 No SCOOT GSA0 = 16
SCOOT LOOP- input allocation:
loops
GSA1 = 17
8 loops allocated to input port 2 -
allocated
GSA2 = 18
inputs 16 to 23.
(255)
GSA3 = 19
GSA4 = 20
GSA5 = 21
GSA6 = 22
GSA7 = 23
GRL2 0 etc
From OTU
GRL2 0 =21 Reply bit function:
input (0)
GRL2 4 =22 Reply words 2, 3, 4, 5 allocated to 8
GRL3 0 =23 SCOOT nibbles.
GRL3 4 =24
GRL4 0 =25 Reply words 0,1 default to OTU
GRL4 4 =26 inputs to provide 16 traffic controller
GRL5 0 =27 reply bits.
GRL5 4 =28