“C” Group: Intelligent Terminal Functions
Configur
ing Dr
iv
P
a
ra
meters
3–54
Output Summary Table - This table shows all twenty-two functions for the logic output 
terminals [11] – [15] at a glance. Detailed function descriptions, related parameters, settings, 
and example wiring diagrams are in 
“C” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
C031
Terminal [11] active 
state
Select logic convention, 
two option codes:
00 normally open N.O.
01 normally closed N.C.
✘ ✔
00
00
00
>C031 OUT-TM
O/C-11        NO
C032
Terminal [12] active 
state
✘ ✔
00
00
00
>C032 OUT-TM
O/C-12        NO
C033
Terminal [13] active 
state
✘ ✔
00
00
00
>C033 OUT-TM
O/C-13        NO
C034
Terminal [14] active 
state
✘ ✔
00
00
00
>C034 OUT-TM
O/C-14        NO
C035
Terminal [15] active 
state
✘ ✔
00
00
00
>C035 OUT-TM
O/C-15        NO
C036
Alarm relay terminal 
active state
✘ ✔
01
01
01
>C036 OUT-TM
O/C-AL        NC
Output Function Summary Table
Option
Code
Terminal 
Symbol
Function Name
Description
00
RUN
Run signal
ON
Inverter is in Run Mode, motor running
OFF
Inverter is in Stop Mode, motor stopped
01
FA1
Frequency arrival type 
1 – constant speed
ON
when output to motor is at the standard set frequency 
F001
OFF
when output to motor is not at the set frequency F001
02
FA2
Frequency arrival type 
2 – over-frequency
ON
when output to motor is at or above the FA threshold 
1(C042) during accel
OFF
when the output to motor is below the FA threshold 1 
(C043) during decel
03
OL
Overload advance 
notice signal (1)
ON
when output current is more than the set threshold for 
the overload signal (set with C041)
OFF
when output current is less than the set threshold for 
the overload signal
04
OD
Output deviation for 
PID control
ON
when PID error is more than the set threshold for the 
deviation signal
OFF
when PID error is less than the set threshold for the 
deviation signal
05
AL
Alarm signal
ON
when the alarm condition has been met and not reset
OFF
when the alarm had not tripped since the previous 
power cycle or since the previous keypad reset