Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
“P” Group: Expansion Card Functions
Configur
ing Dr
iv
P
a
ra
meters
3–66
NOTE: Parameters P044 to P049 are available only in inverters with manufacturing code 
x8K xxxxxx xxxxx or later. The manufacturing code is printed on the product specifications 
labels, located on the front and side of the inverter housing.
P022
Feed-forward gain 
setting
Range is 0.00 top 99.99 / 
100.0
✘ ✔ 0.00 0.00 0.00
>P022 FEEDBACK
FFWG      000.00
P023
Position loop gain 
setting
Range is 0.00 to 99.99 / 
100.0
✘ ✔ 0.50 0.50 0.50
>P023 FEEDBACK
G         000.50
P025
Temperature compensa-
tion thermistor enable
Allows for motor-mounted 
thermistor to calibrate 
output to motor temperature
Two option codes:
00 Disable
01 Enable
✘ ✔
00
00
00
>P025 FEEDBACK
R2-ADJ       OFF
P026
Over-speed error
detection level setting
Range is 0.0 to 150.0%
✘ ✔
135.0
135.0
135.0
%
>P026 FEEDBACK
0SPD      135.0%
P027
Speed deviation error 
detection level setting
Range is 0.00 to 99.99 / 
120Hz
✘ ✔ 7.50 7.50 7.50
>P027 FEEDBACK
NER     007.50Hz
P031
Accel/decel time input 
selection
Three options:
00 Inverter
01 Expansion card 1
02 Expansion card 2
✘ ✘
00
00
00
>P031 ACC/DEC
SELECT       REM
P032
Positioning command 
input selection
Three options:
00 Inverter
01 Expansion card 1
02 Expansion card 2
✘ ✔
00
00
00
>P032 P-SET
SELECT       REM
P044
DeviceNet comm 
watchdog timer
Range is 0.00 99.99 seconds
✘ ✘
1.00
1.00
1.00
>P044 DEVICENET
TIMER     01.00s
P045
Inverter action on 
DeviceNet comm error
Five options:
00 Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
✘ ✘
01
01
01
>P045 DEVICENET
T-OUT        FTP
P046
DeviceNet polled I/O: 
Output instance number
Three settings:
20, 21, 100
✘ ✘
21
21
21
>P046 DEVICENET
O-AS-INS     021
P047
DeviceNet polled I/O: 
Input instance number
Three settings:
70, 71, 101
✘ ✘
71
71
71
>P047 DEVICENET
O-AS-INS     071
P048
Inverter action on 
DeviceNet idle mode 
Five options:
00 Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
✘ ✘
01
01
01
>P048 DEVICENET
IDLE         FTP
P049
DeviceNet motor poles 
setting for RPM
Range is 00 to 38 (even 
numbers only)
✘ ✘
0
0
0
poles
>P049 DEVICENET
P            00P
“P” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)