Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
SJ300 Inverter
Getti
n
g Star
ted
1–11
Derating Curves
The maximum available inverter current output is limited by the carrier frequency and ambient 
temperature. The carrier frequency is the inverter’s internal power switching frequency, settable 
from 0.5 kHz to 12 kHz. Choosing a higher carrier frequency tends to decrease audible noise, 
but it also increases the internal heating of the inverter, thus decreasing (derating) the maximum 
current output capability. Ambient temperature is the temperature just outside the inverter 
housing—such as inside the control cabinet where the inverter is mounted. A higher ambient 
temperature decreases (derates) the inverter’s maximum current output capacity.
Use the following derating curves to help determine the optimal carrier frequency setting for 
your inverter, and to find the output current derating. Be sure to use the proper curve for your 
particular SJ300 inverter model number.
SJ300 1.5 to 22 kW at 50 deg. C ambient
2
4
6
8
10
12
14 15
0.5
65%
70%
75%
80%
85%
90%
95%
100%
Carrier Frequency (kHz)
%
 of Driv
e’
s Rated Amps
004 to 150L
185L
220L
SJ300 30 to 55 kW at 50 deg. C ambient
2
4
6
8
10
12
14 15
0.5
65%
70%
75%
80%
85%
90%
95%
100%
Carrier Frequency (kHz)
% of Dri
ve’
s Rated
 Amp
s
370L
300L
450L
550L
450L
550L