Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
Orientation to Inverter Features
In
v
e
rt
er Moun
ting
and Install
a
tion
2–4
3. Third-level access - The SJ300  
provides for field installation of 
interface circuits. These circuits are 
on expansion cards, to be installed in 
the expansion bay. To access the 
expansion bay, you will need to 
remove the upper front panel. Use 
the latch to release the digital 
operator (the panel filler plate may 
remain). Remove the two retention 
screws the bottom corners of the 
upper front panel. Lift up at the 
bottom, then disengage the two 
hinge latches at the top.
The expansion bay has two sites for 
adding expansion cards. Each card 
connects via the interface connector, 
and mounts using three standoff 
screw locations. Further details on 
accessories are in Chapter 5. You 
may also refer to the instruction 
manual that comes with each type of 
expansion card.
The following sections will describe the system design and guide you through a step-by-step 
installation process. After the section on wiring, this chapter will show how to use the front 
panel keys to access functions and edit parameters.
Latch to release digital operator
Retention screws
Expansion bay
Expansion connectors