Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
Using the Front Panel Keypad
In
v
e
rt
er Moun
ting
and Install
a
tion
2–24
• Function Key – This key is used to navigate 
through the lists of parameters and functions 
for setting and monitoring parameter values.
• Up/Down ( ,  
) Keys – Use these 
keys alternately to move up or down the lists 
of parameter and functions shown in the 
display, and increment/decrement values.
• Store ( 
 ) Key – When the unit is in 
Program Mode and the operator has edited a 
parameter value, press the Store key to write 
the new value to the EEPROM. This param-
eter is then displayed at powerup by default. 
If you want to change the powerup default, 
navigate to a new parameter value and press 
the Store key.
Keys, Modes, and 
Parameters
Purpose of the keypad is to provide a way to change modes and parameters. The term function 
applies to both monitoring modes and parameters. These are all accessible through function 
codes
 that are primarily 3 or 4-character codes. The various functions are separated into related 
groups identifiable by the left-most character, as the table shows.
For example, function “A004” is the base frequency setting for the motor, typically 50 Hz or 
60 Hz. To edit the parameter, the inverter must be in Program Mode (PGM LED will be ON). 
You use the front panel keys to first select the function code “A004.” After displaying the value 
for “A004,” use the Up/Down ( 
 or 
) keys to edit the value.
NOTE: The inverter 7-segment display shows lower case “b” and “d”, meaning the same as the 
upper case letters “B” and “D” used in this manual (for uniformity “A to F”).
 The inverter automatically switches into Monitor 
Mode when you access “D” Group functions. It 
switches into Program Mode when you access 
any other group, because they all have editable 
parameters. Error codes use the “E” Group, and 
appear automatically when a fault event occurs. 
Refer to 
 for error code details.
Function
key
Up/Down
keys
Store
key
Hz
POWER
A
RUN
PRG
RUN
STOP
RESET
MIN
MAX
HITACHI
FUNC
1
2
%
ALARM
STR
V
kW
5 0.0
1
2
STR
Function 
Group
Type (Category) of Function
Mode to Access
PGM LED 
Indicator
“D”
Monitoring functions
Monitor
 or 
“F”
Main profile parameters
Program
“A”
Standard functions
Program
“B”
Fine tuning functions
Program
“C”
Intelligent terminal functions
Program
“H”
Motor constant functions
Program
“P”
Expansion card functions
Program
“U”
User-selectable menu functions
Monitor
“E”
Error codes
1
2
“D” Group
“A” Group
“B” Group
“C” Group
“H” Group
“P” Group
“U” Group
“F” Group
MONITOR