“D” Group: Monitoring Functions
Configur
ing Dr
iv
P
a
ra
meters
3–6
“D” Group: Monitoring Functions
Parameter 
Monitoring 
Functions
You can access important system parameter values with the “D” Group monitoring functions, 
whether the inverter is in Run Mode or Stop Mode. After selecting the function code number 
for the parameter you want to monitor, press the Function key once to show the value on the 
display. In Functions D005 and D006 the intelligent terminals use individual segments of the 
display to show ON/OFF status.
“D” Function
Run 
Mode
Edit
Range 
and Units
SRW Display
Func.
Code
Name
Description
D001
Output frequency monitor
Real-time display of output 
frequency to motor, from 0.0 to 
400.0 Hz
0.0 to 
400.0 Hz
FM     0000.00Hz
D002
Output current monitor
Filtered display of output current 
to motor (100 mS internal filter 
time constant)
A
Iout     0000.0A
D003
Rotation direction 
monitor
Three different indications:
“F”. Forward
“o”. Stop
“r”   Reverse
Dir         STOP
D004
Process variable (PV), 
PID feedback monitor
Displays the scaled PID process 
variable (feedback) value (A75 is 
scale factor)
PID-FB  0000.00%
D005
Intelligent input terminal 
status
Displays the state of the intelligent 
input terminals:
IN-TM  LLLLLLLLL
D006
Intelligent output terminal 
status
Displays the state of the intelligent 
output terminals:
OUT-TM    LLLLLL
D007
Scaled output frequency 
monitor
Displays the output frequency 
scaled by the constant in B86. 
Decimal point indicates range:
XX.XX   0.00 to 99.99
XXX.X   100.0 to 999.9
XXXX.   1000 to 9999
XXXX     10000 to 99990
User-
defined
F-CNV  000000.00
D012
Torque monitor
Estimated output torque value, 
range is -300.0 to +300.0%
%
TRQ        +000%
D013
Output voltage monitor
Voltage of output to motor,
range is 0.0 to 600.0V
VAC
Vout      000.0V