SJ300 Inverter
Configur
ing Dr
iv
P
a
ra
met
e
rs
3–21
Acceleration 
Pause Function
The acceleration pause function can be 
used to minimize the occurrence of 
over-current trips when accelerating 
high inertia loads. It introduces a dwell 
or pause in the acceleration ramp. You 
can control the frequency at which this 
dwell occurs (A069), and the duration 
of the pause time (A070). This function 
can also be used as an anti-windmilling 
tool, when the load might have a 
tendency to drive the motor in a reverse 
direction while the inverter is in a Stop mode. Initiating a normal acceleration in such a situa-
tion may result in over-current trips. This function can be used to keep the inverter output 
frequency and voltage at low levels long enough to bring the load to a stop, and commence 
turning in the desired direction before the acceleration ramp resumes. See also 
“A” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
A063
A065
A067
Jump (center) frequency 
setting
Up to 3 output frequencies 
can be defined for the output 
to jump past to avoid motor 
resonances (center 
frequency)
Range is 0.00 to 400.0 Hz
✘ ✔ 0.00 0.00 0.00
Hz
>A063 JUMP
F1     0000.00Hz
>A065 JUMP
F2     0000.00Hz
>A067 JUMP
F3     0000.00Hz
A064
A066
A068
Jump (hysteresis) 
frequency width setting
Defines the distance from 
the center frequency at 
which the jump occurs
Range is 0.0 to 10.0 Hz
✘ ✔ 0.50 0.50 0.50
Hz
>A064 JUMP
W1       00.50Hz
>A066 JUMP
W2       00.50Hz
>A068 JUMP
W3       00.50Hz
Accel pause 
period
Output
frequency
A070
A069
Set frequency
t
0
“A” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
A069 Acceleration pause 
frequency setting
Range is 0.00 to 400.0Hz
✘ ✔ 0.00 0.00 0.00
Hz
>A069 F-STOP
F      0000.00H
A070 Acceleration pause time 
setting
Range is 0.0 to 60.0 sec.
✘ ✔
0.0
0.0
0.0
sec.
>A070 F-STOP
T          00.0s