Hitachi hitachi series inverter 사용자 설명서
82
“P” Function
Defaults
Func.
Code
Name
Description
Run
Mode
Edit Initial data Units
p041
Speed / Torque control
switching time
switching time
Set range is 0 to 1000 ms
U
0.
ms
P044
Communication watchdog
timer
(for option)
Set range is 0.00 to 99.99s
U
1.00
s
P045
Inverter action on
communication error
(for option)
communication error
(for option)
00 (tripping),
01 (tripping after decelerating and
01 (tripping after decelerating and
stopping the motor),
02 (ignoring errors),
03 (stopping the motor after
03 (stopping the motor after
free-running),
04 (decelerating and stopping the
motor)
U
00
-
P046
DeviceNet polled I/O:
Output instance number
Output instance number
0-20
U
1
-
P048
Inverter action on
communication idle mode
communication idle mode
00 (tripping),
01 (tripping after decelerating and
01 (tripping after decelerating and
stopping the motor),
02 (ignoring errors),
03 (stopping the motor after
03 (stopping the motor after
free-running),
04 (decelerating and stopping the
motor)
U
00
-
P049
Motor poles setting for RPM
0/2/4/6/8/10/12/14/16/18/20/22/24/
26/28/30/32/34/36/38/40/42/44/46/48
26/28/30/32/34/36/38/40/42/44/46/48
U
0
Poles
p055
Pulse train input frequency
scale setting
scale setting
Sets the pulse numbers at max.
frequency, set range is 1.0~32.0 kHz
frequency, set range is 1.0~32.0 kHz
U
25.0
kHz
p056
Pulse train input frequency
filter time constant setting
filter time constant setting
Set range is 0.01~2.00 sec.
U
0.10
sec
p057
Pulse train input bias setting
Set range is –100~100 %
U
0.
%
p058
Limitation of the pulse train
input setting
input setting
Set range is 0~100 %
U
100.
%
P060
Multistage position 0
0
Pulse
s
P061
Multistage position 1
0
Pulse
s
P062
Multistage position 2
0
Pulse
s
P063
Multistage position 3
0
Pulse
s
P064
Multistage position 4
0
Pulse
s
P065
Multistage position 5
0
Pulse
s
P066
Multistage position 6
0
Pulse
s
P067
Multistage position 7
P073 to P072
(Displayed higher 4-digits only)
0
Pulse
s
P068
Homing mode selection
00…Low speed mode
01…High speed mode
01…High speed mode
00
-
P069
Homing direction
00…Forward rotation side
01…Reverse rotation side
01…Reverse rotation side
01
-
P070
Low speed homing freq.
0 to 10Hz
5.00
Hz
P071
High speed homing freq.
0 to 400Hz
5.00
Hz