Lincoln Electric SVM179-B 사용자 설명서

다운로드
페이지 103
OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING & REPAIR
F-6
F-6
LN-25™ PRO
Variable or “hunting” arc.
1. Wrong size, worn or melted tip.
2. Worn  work  cable  or  poor  con-
nection.
3. Wrong polarity’
4. The  gas  nozzle  is  extended
beyond  the  contact  tip  or  the
wire stickout is too long.
5. Poor gas shielding on process-
es requiring gas.
1. Replace the tip.
2. Verify  all  the  work  and  elec-
trode connections are tight and
in good condition Clean if nec-
essary and replace.
3. Adjust polarity to recommended
procedure  verify  DIP  switch  7
setting  matches  the  electrode
polarity.
4. Adjust  the  gas  nozzle  and
shorten  the  stickout  to  1/2  to
3/4 inches.
5. Check  gas  flow  and  mixture.
Remove  or  block  sources  of
drafts.    Perform  the  GAS
SOLENOID  T
EST, replace  if
necessary.
The preset voltage does not match
the power source voltage.
(Digital display models)
The preset voltage calibration in the
feeder has been selected for a dif-
ferent power source.
Use the setup menu to change the
preset  voltage  in  the  feeder  to
match the power source.
When the trigger is pulled, the wire
feeds slowly.
(Digital display models)
The Run-in switch is “ON”
Turn the run-in switch to the “OFF”
position.
Poor  arc  starts  with  sticking  or  “
Blast-offs”, weld porosity, narrow or
ropy looking beads.
Improper procedures or techniques.
See “Gas metal arc welding guide”
(GS-100)