FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING AND REPAIR
F-8
F-8
POWER WAVE 355M/405M
Auxiliary  receptacle  is  “dead”  no
auxiliary voltage.
1.  Circuit  breaker  CB1  (on  case
front) may have opened.  Reset.
2.  Circuit  breaker  CB3  (in  recon-
nect  area)  may  have  opened.
Reset.
3.  On  PW  405  models,  the  circuit
breaker  CB4  protects  the
220VAC  receptacle.    Reset  if
tripped.
1.  Perform the Auxiliary
A fault or error code is displayed.
General  degradation  of  the  weld
performance.
1.  Check  for  feeding  problems,
bad  connections,  excessive
loops in cabling, etc.
2.  Verify  weld  mode  is  correct  for
processes.
3.  The  power  source  may  require
calibration.
4.  Check  the  actual  current  dis-
played  on  the  Power  Feed  10
vs.  actual  current  measured  via
external meter.
5.  Check  the  actual  voltage  dis-
played  on  the  Power  Feed  10
vs. actual voltage measured via
external meter.
6.  Check the actual WFS displayed
on the Power Feed 10 vs. actual
WFS  measured  via  external
meter.
1.  Perform the Voltage and
Current Calibration Procedure
using the Power Wave software
program.
2.  Perform the Current
2.  Perform the Output Diode
5.  The control board may be
faulty.