JVC DT-R24L41D 사용자 설명서

다운로드
페이지 28
18
External Control
About the external control
This monitor has three external control terminals.
MAKE/TRIGGER terminal (RJ-45): The following external control 
systems are available.
(1) MAKE (make contact) system: Controls the monitor by 
short-circuiting the corresponding pin terminal to the GND pin 
terminal, or disconnecting (opening) it.
(2) TRIGGER (trigger) system: Controls the monitor by sending 
the pulse signal instantaneously to the corresponding pin 
terminal.
 ☞ “Using the MAKE/TRIGGER system” on the right
RS-485 terminals (RJ-45): Controls the monitor with the RS-485 
system (
☞ “Using the serial communication” on page 20).
RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-
232C system (
☞ “Using the serial communication” on page 20).
Set the following items of “REMOTE SETTING” in SET-UP MENU 
according to the external control terminal and control system 
(
☞ “SERIAL TYPE,” “PARALLEL TYPE” on page 16).
Control 
terminal
Control system
The settings of this unit
“SERIAL 
TYPE” 
setting
“PARALLEL 
TYPE” 
setting
MAKE/
TRIGGER 
terminal
MAKE 
MAKE
TRIGGER
TRIGGER
RS-485 
terminal
Serial 
communication 
RS-485
RS485*
1
RS-232C 
terminal
RS-232C
RS232C*
1
*1
 For a monitor connected to a personal computer etc, select 
the terminal the equipment is actually connected to. For other 
monitors, select “RS485.”
Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu 
on the monitor
You can use external control even when “CONTROL LOCK” is set 
to “VOL.LOCK” or “ALL LOCK” (
☞ page 17).
When the monitor is off (on standby), external control is not 
available. But certain external controls (starting/terminating 
communication, turning on the monitor) are available through the 
serial communication (
☞ page 21).
<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated 
controller*
2
.
“Using the MAKE/TRIGGER system” on the right.
*2
 The controller is not commercially available. Consult your dealer if 
you need it.
<Serial communication>
PC, etc.
RS-485 IN
or
RS-232C
RS-485 
OUT
RS-485
 IN
RS-485 
OUT
RS-485
 IN
RS-485 
OUT
For the details, see page 20.
„
Using the MAKE/TRIGGER system
The MAKE/TRIGGER terminal is confi gured as follows. You can assign 
a function to each pin terminal in “REMOTE SETTING” (
☞ “PIN1, PIN2, 
PIN3, PIN4, PIN5” in “PARALLEL TYPE” on page 16).
You cannot change the functions assigned to the pin terminals from 
6th to 8th.
Pin No.
Pin name
1
PIN1
2
PIN2
3
PIN3
4
PIN4
5
PIN5
This is a female terminal.
6
TALLY*
1
7
ENABLE*
2
8
GND
*1
 The 6th pin terminal controls turning on or off the tally lamp 
(available to control even when the 7th pin terminal is invalid).
*2
 The 7th pin terminal makes the external control valid/invalid. Make 
sure to control the terminal by the MAKE system.
To assign the functions to the pin terminals
For the operation procedure, see page 12.
1
  Select “REMOTE SETTING” on the SET-UP MENU.
2
  Set “PARALLEL TYPE” to “SET.”
3
  Select a pin name (“PIN1” – “PIN5”) for which you want to assign 
a function, then select the function you want to assign.
For the selectable functions, see the table on page 19.
Operation of the external control
1
  Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” or 
“TRIGGER” in the SET-UP MENU.
2
  Short-circuit the 7th pin terminal (ENABLE) to the 8th pin terminal 
(GND) so that the monitor can be controlled by the external 
control.
3
  When the “MAKE” system is selected: Operate each function 
by short-circuiting the corresponding pin terminal to the 8th pin 
terminal (GND) or opening it.
When the “TRIGGER” system is selected: Operate each function 
by pulse control, that is short-circuiting the corresponding pin 
terminal to the 8th pin terminal (GND) for about 1 second and 
opening it.
When changing the input with MAKE system, only one pin terminal 
must be short-circuited. (Other pin terminals must be opened.)
When selecting the “TRIGGER” system, you can operate only one 
function at a time. Operate the functions one by one.
„
DT-R24_17L4D_US_EN.indb   18
DT-R24_17L4D_US_EN.indb   18
2011/01/20   16:21:47
2011/01/20   16:21:47