7.3  Compliance of a Combustible Mantel Shelf 
To ensure compliance of an existing mantel shelf or to install a combustible mantel shelf, 
refer to table and figure below. For example, a mantel shelf with a 6’’ depth (152 mm) ((X) 
value) must be installed at least 29" (737 mm) ((I) value) above the top of the insert (see 
figure below). Different mantel shelf dimensions are listed in the following table. However, 
no  combustible  mantel  shelf  can be  installed  at  less  than  29"  (737 mm) above  the top of 
the  insert.    If  the  depth  of  the  mantel  shelf  is  not  listed  in  the  table  below,  add  23"  (584 
mm) to the depth of your mantel shelf to obtain the safe positioning of your mantel shelf. 
For example, for a 9" (229 mm) mantel shelf, the safe positioning would be 32" (813 mm) 
above the top of the insert (23" (584 mm) + 9" (229 mm)). 
 
 
 
 
 
MAXIMUM MANTEL 
SHELF DIMENSION 
(X) 
MANTEL SHELF 
CLEARANCES 
(I) 
6" / 152 mm 
29" (737 mm) 
8" / 203 mm 
31" (787 mm) 
10" / 254 mm 
33" (838 mm) 
12" / 305mm 
35" (889 mm)