IBM 61Y 사용자 설명서

다운로드
페이지 226
 
 Using IBM ServeRAID
 139
— A number (1–16) that specifies the new concurrent drive startup 
count
— A number (1–16) that specifies the new concurrent drive startup 
count and a number (3–15) that specifies the startup delay time, in 
seconds.
RAID Configuration commands
The IPSSEND RAID configuration commands include the following: 
drivever
 Use the drivever function to display the vendor ID, microcode version, and 
serial number of a SCSI device.  The IPSSEND program retrieves this 
information directly from the device. 
Supported operating systems:  Windows NT, OS/2, NetWare, Linux, 
OpenServer, UnixWare, and DOS
Command:
ipssend drivever 
controller channel sid
where: 
controller is the ServeRAID controller number (1–12)
channel is the channel number for the device (1, 2, or 3)
sid is the SCSI ID for the device (0–15)
getconfig
Use the getconfig function to display the ServeRAID controller configuration 
information.  This includes information about the firmware version; initiator 
ID and rebuild rate; logical-drive status, RAID level, and size; and physical 
device type, SCSI ID, and PFA error. 
Supported operating systems:  Windows NT, OS/2, NetWare, Linux, 
OpenServer, UnixWare, and DOS
Command:
ipssend getconfig
 controller options
where: 
controller is the ServeRAID controller number (1–12)
options is one of the following: 
— AD for the controller information
— LD for the logical drive information
— PD for the physical device information
— AL for all information. This is the default option.
hsrebuild
Use the hsrebuild function to turn on the ServeRAID controller hot-swap 
rebuild feature or display the current status of the hot-swap rebuild feature. 
Supported operating systems:  Windows NT, OS/2, NetWare, Linux, 
OpenServer, UnixWare, and DOS
Command:
ipssend hsrebuild 
controller options
where: 
controller is the ServeRAID controller number (1–12)
options is one of the following: 
— ON enables the hot-swap feature
— ? displays the status of the hot-swap rebuild feature.
readahead
Use the readahead function to enable, disable, or set the adaptive mode for 
the read-ahead feature of the ServeRAID controller.