IBM 61Y 사용자 설명서

다운로드
페이지 226
 140
Hardware Maintenance Manual: xSeries 250
 
 
Supported operating systems:  Windows NT and DOS
Command:
ipssend readahead
 controller options
where: 
controller is the ServeRAID controller number (1–12)
options is one of the following: 
— ON enables the read-ahead feature
— OFF disables the read-ahead feature
— ADAPTIVE indicates that the controller will determine the best mode 
to use at any given time.
— ? displays the current read-ahead feature mode being used.
stripesize
Use the stripesize function to set the size of the ServeRAID controller's stripe 
to 8 KB, 16 KB, 32 KB, or 64 KB. 
Supported operating systems:  DOS
Command:
ipssend stripesize 
controller options
where: 
controller is the ServeRAID controller number (1–12)
options is one of the following: 
— 8 to set the stripe-unit size to 8 KB
— 16 to set the stripe-unit size to 16 KB
— 32 to set the stripe-unit size to 32 KB
— 64 to set the stripe-unit size to 64 KB
— ? to display the current stripe-unit size being used
unattended
Use the unattended command to enable or disable the unattended feature of 
the ServeRAID controllers. 
Supported operating systems:  Windows NT, OS/2, NetWare, Linux, 
OpenServer, Unixware, and DOS
Command:
ipssend unattended 
controller options
where: 
controller is the ServeRAID controller number (1–12)
options is one of the following: 
— ON to enable the feature
— OFF to disable the feature
— ? to display the current setting of this feature
Starting the IPSMON program
You can run the IPSMON program from the operating system command line.
To start the IPSMON program: 
If you are using OS/2 or Windows NT: 
1.
Type: 
c:\ipsadm\ipsmon
where c is the drive letter of the drive where OS/2 or Windows NT is 
installed.