 Diagnostics
 41
UNIX messages
This section provides descriptions of the Ethernet error messages for the SCO UNIX 
LLI driver, and suggested actions to resolve each problem.
Table 4. NDIS (Windows NT) driver messages for the Ethernet controller. 
PermaNet
 Server:
No Secondary Adapter Found.  Grouping Mode is disabled.  
Explanation:  
The failover option requires an adapter that is compatible with the device 
driver of the Ethernet controller on the system board.  No such adapter was found.  
Action:  
Make sure the correct adapter is installed.       
PermaNet Server:  
Problem Occurs on the Primary Adapter.  Switching over to the Secondary Adapter.  
Explanation:  
The system detected a problem with the primary Ethernet connection and 
has transferred all network traffic to the secondary Ethernet controller.  
Action:  
identify the cause of the failure on the primary Ethernet connection.  Restoring 
the operational state of the primary connection will cause the network traffic to 
automatically transfer to the primary Ethernet controller.
PermaNet Server: 
Switching back to Primary Adapter.  
Explanation:  
The primary Ethernet connection is now operating correctly.  Network 
traffic will automatically transfer to the primary Ethernet controller.  
Action:  
None needed, message is for information only.    
Table 5. UNIX LLI driver messages for the Ethernet controller. 
pnt0-2
PCI search specified, PCI device not found!
 
Explanation:  
The driver cannot locate the Ethernet controller on the PCI bus.  
Action:
 
Run the NETCONFIG program to search for another Ethernet controller
Verify that the Ethernet controller is enabled.  If the Ethernet controller is enabled, run the 
diagnostic programs.
pnt0-6
Cannot allocate memory for the adapter during an interrupt.  Please check the Streams 
parameters.  
Explanation:  
On a SunSoft Solaris system, this message indicates that the system is out of 
Streams memory blocks.  
Action:  
Use the CRASH utility to increase the number of Streams memory blocks.  Modify the 
interrupt request (IRQ) settings in the Configuration/Setup Utility program, or run the 
NETCONFIG program to match the hardware settings.
pnt0-7
Cannot allocate memory for the adapter during reset.  Please check the Streams parameters.  
Explanation:  
The system is out of Streams memory blocks.  
Action:  
Use the CRASH utility to increase the number of Streams memory blocks.
pnt0-11
Device not found!
 
Explanation:  
The driver cannot find an Ethernet controller.  
Action:  
Verify that the Ethernet controller is enabled.  If the Ethernet controller is enabled, run 
the diagnostic programs.