Intel cpb4612 사용자 설명서

다운로드
페이지 104
 
 27
Chapter 
5
5
 
 
5  System Monitoring and Control 
The cPB4612 has an IPMI System Monitor that complies with PICMG
® 2.9 specification, and complies 
with IPMI Specification 1.5.  This allows a PICMG 2.9 compliant chassis that utilizes a chassis manager, 
or Baseboard Management Controller (BMC) to detect the presence of the cPB4612 and make Field 
Replaceable Unit (FRU) information, and Sensor Device Records (SDR’s) available.  Sensors monitor 
voltages, CPU and system temperature, and other inputs, including the front latch, which can generate 
events that are recorded in the BMC’s System Event Log (SEL).  The IPMI System Monitor has both an 
IPMB and a dedicated basic serial interface, so that it is possible for the cPB4612 to acquire FRU and 
sensor information directly from the IPMI System Monitor.  The firmware on the IPMI System Monitor can 
be upgraded via the serial interface or over IPMB.