Dialogic M7324 사용자 설명서

다운로드
페이지 178
Dialogic
®
 PBX Integration Board User’s Guide  
The MWI feature access code must be programmed in specific personal keys 
in the Mitel 430 and Mitel 420 emulations for the board to function 
successfully.  
There are specific switch programming requirements that apply if using a 
Dialogic
® 
PBX Integration Board with a Mitel Superswitch. Pay attention to 
set these features exactly (and assigned to the right keys) so that the PBX 
Integration Board and the Dialogic
® 
Unified API can function correctly.  
The PBX uses Class of Service (COS) to determine which features are 
available to an extension. The features available to an extension are shown in 
the telephone set’s LCD Features display. Any feature not in the COS will not 
be displayed. 
The following subsections describe PBX-side programming, followed by 
Phone-side programming. 
PBX-Side Programming 
Mitel SX-200 PBX Programming Requirements for Using MWI:  
1.  Under main menu option 03, COS Define, enable option numbers 232, 
Message Waiting Setup – Lamp and 259, Message Sending.  
2.  Under main menu option 09, Stations/Superset Assignments, scroll 
down to select the desired station(s), arrow over to the COS column and 
enter the desired COS number (based on the COS setup above). 
3.  Press <ESC>0 to enter the change and <ESC>6 to return to the main 
menu. 
Mitel SX-2000 PBX Programming Requirements for using MWI: 
1.  Create a COS from the main menu option System Forms | Class of 
Service Options Assignments
2.  Press <ESC>2 to edit this form and enter the COS number desired for 
MWI setup. 
3.  Press <ESC>1 to recall the select COS number to the screen. 
4.  Set the Message Waiting option to YES. 