CDM-600 Satellite Modem 
Revision 7 
Connector Pinouts 
MN/CDM600.IOM 
5–3 
5.4 
Data Interface Connector (P3B) 
The Data Interface connector, a 25-pin D type female, conducts data input and output 
signals to and from the modem, and connects to customer’s terrestrial equipment, 
breakout panel, or protection switch. Refer to Table 5-4 for pin assignments. 
Table 5-4.  Data Interface Connector Pin Assignments 
Pin # 
Generic Signal 
description 
Direction 
EIA-422 
EIA 530 
LVDS 
V.35 
EIA-232  
Circuit # 
Transmit Data A 
DTE to Modem 
SD A  
SD A  
BA 
103 
14 
Transmit Data B 
DTE to Modem 
SD B 
SD B 
103 
24 
Transmit Clock A 
DTE to Modem 
TT A  
SCTE A  
DA 
113 
11 
Transmit Clock B 
DTE to Modem 
TT B 
SCTE B 
113 
15 Internal 
Transmit 
Clock A 
Modem to DTE 
ST A  
SCT A 
DB 
114 
12 Internal 
Transmit 
Clock B 
Modem to DTE 
ST B 
SCT B 
114 
Receive Data A 
Modem to DTE 
RD A  
RD A 
BB 
104 
16 
Receive Data B 
Modem to DTE 
RD B 
RD B 
104 
17 
Receive Clock A 
Modem to DTE 
RT A  
SCR A 
DD 
115 
Receive Clock B 
Modem to DTE 
RT B 
SCR B 
115 
Receiver Ready A 
Modem to DTE 
RR A  
RLSD * 
CF 
109 
10 
Receiver Ready B 
Modem to DTE 
RR B 
109 
23 
External Carrier Off  
(EIA-232  ‘1' or TTL 
‘low’ ) 
DTE 
to 
Modem 
- - - - 
Signal Ground 
SG  
SG  
AB 
102 
1 Shield 
Shield FG 
AN  101 
Notes:  
1.  Receiver Ready is an EIA-232 -level control signal on a V.35 interface. 
2.   DO NOT connect signals to pins which are not shown - these pins are reserved for use by the redundancy 
system. 
3.  ‘B’ signal lines are not used for EIA-232 applications. 
4.  For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the Modem is DTE, and ignore 
Transmit clocks if the Modem is DCE. 
5.  For IDR operation using G.703, this primary interface becomes the 8 kbps EIA-422 overhead channel.