Premier Mounts CDM-600 사용자 설명서

다운로드
페이지 250
CDM-600 Satellite Modem 
Revision 7 
Connector Pinouts 
MN/CDM600.IOM 
5–5 
5.7 
IDR Backward Alarms Connector (P5A) 
The IDR Alarm interface connection is a 15-pin female connector located on the rear 
panel of the modem. Refer to Table 5-7 for pin assignments. 
Table 5-7.  IDR Alarm Interface Connector Pin Assignments 
Pin # 
Signal Function 
Name 


Backward Alarm 1 is active 
 
Backward Alarm 1 is not active 
BA-1-NO 
BA-1-COM 
BA-1-NC 
10 TBD 
MON-A 

11 
Backward Alarm 2 is active 
 
Backward Alarm 2 is not active 
BA-2-NO 
BA-2-COM 
BA-2-NC 

13 
Backward Alarm 3 is active 
 
Backward Alarm 3 is not active 
BA-3-NO 
BA-3-COM 
BA-3-NC 
14 TBD 
MON-B 

15 
Backward Alarm 4 is active 
 
Backward Alarm 4 is not active 
BA-4-NO 
BA-4-COM 
BA-4-NC 
12 Ground 
GND 
5.8 Unit 
Alarms 
(P5B) 
 
Unit alarms are provided on a 15-pin male connector located on the rear panel of the 
modem. Refer to Table 5-8 for pin assignments. 
Table 5-8.  Alarm Interface Connector Pin Assignments 
Pin # 
Signal Function 
Name 

15 
Rx Traffic (De-energized, Faulted) 
Rx Traffic (Energized, No Fault) 
RX Traffic 
RX-NC 
RX-NO 
RX-COM 
14 

13 
Tx Traffic (De-energized, Faulted) 
Tx Traffic (Energized, No Fault) 
Tx Traffic 
TX-NC 
TX-NO 
TX-COM 

12 
Unit Fault (De-energized, Faulted) 
Unit Fault (Energized, No Fault) 
Unit Fault 
UNIT-NC 
UNIT-NO 
UNIT-COM 
11 
RX I Channel  (Constellation monitor) 
RX Q Channel  (Constellation monitor) 
RX-I 
RX-Q 
10 No 
Connection 
N/C 
AGC Voltage (Rx signal level, 0 to 2.5 volts)  
AGC 
EXT Carrier OFF 
EXT-OFF 
1 Ground 
GND