MRV Communications TS5000/4U1/V*) 사용자 설명서
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
13
Air RX Flag LED
Green LED indicates data received by the Airlink
receiver. Turns ON at the threshold level.
Air RX Sync LED
Yellow LED. Turns ON if the rate of the received
Data matches the Data Rate set on the Data Rate
Data matches the Data Rate set on the Data Rate
DIP switch.
F/O Main, RX Flag
LED
LED
Upper green LED indicates Data received by the
Fiber Optic receiver. Turns ON at the threshold
Fiber Optic receiver. Turns ON at the threshold
level.
F/O Main, RX Sync
LED
LED
Lower green LED. Turns ON if the rate of the
received Data matches the Data Rate set on the
received Data matches the Data Rate set on the
Data Rate DIP switch.
F/O Redundant, RX
Flag LED
Flag LED
(Optional)
Upper green LED indicates Data received by the
Fiber Optic receiver. Turns ON at the threshold
Fiber Optic receiver. Turns ON at the threshold
level.
F/O Redundant, RX
Sync LED
(Optional)
(Optional)
Lower green LED. Turns ON if the Fusion is
active and there is synchronization with the
received Data.
received Data.
Optical Power 7-
segment display
segment display
Digital readout indicates the Optical Power level
received by the Airlink receiver.
received by the Airlink receiver.
Alignment LED
Yellow LED. Turns ON if the Alignment
Operating Mode is selected.
Operating Mode is selected.
Loop LED
Yellow LED. Turns ON in LOOPBACK mode.
Flashing in Remote Loop mode.
Fusion LED
Yellow LED. Turns ON if the Fusion mode is
enabled.
enabled.
Flashing when the Fusion (radio back-up system) is
active.
active.
Heating LED
Yellow LED. Turns ON if the heating mode is
selected (Heating is enabled).
SW Mode LED
Red LED. Turns ON if the SW Mode
(SOFTWARE) Operating Mode is selected.
(SOFTWARE) Operating Mode is selected.
Lasers status LEDs
There are 3 LEDs – L1, L2, L3 indicating if the
lasers are switched on or off. If the LED is
switched off, the laser is switched off. If the LED is
switched off, the laser is switched off. If the LED is
switched ON, the laser is switched ON.
When the DIP switch toggle #3 is moved to ON
When the DIP switch toggle #3 is moved to ON
position the LED L1 and its corresponding laser
will turn off
will turn off
PS1
Green LED. Turns ON when main power supply is
active
PS2
Green LED. Turns ON when redundant power
supply is active
supply is active
Heater ON
Green LED. Turns ON when the heating of the
front window is active.
The heating will start operating only if one of the
The heating will start operating only if one of the
following conditions is present: or the temperature
is lower than 15
is lower than 15
o
C; or the humidity level in the air is
above 80%. There is a controller with a thermostat
inside the TereScope, which controls the heating in
inside the TereScope, which controls the heating in
accordance with the above conditions. (The heating
option is not standard, and exists only if purchased)
option is not standard, and exists only if purchased)
Management TX
Flashing when the RSM-SNMP is connected and
the TereScope is transmitting management Data.
the TereScope is transmitting management Data.
(There is no Link indication)
Indicators
(7-segment
display and
LEDs)
Management RX
Flashing when the RSM-SNMP is connected and
the TereScope is receiving management Data.
the TereScope is receiving management Data.
(There is no Link indication)