Cisco Systems 57712 사용자 설명서

다운로드
페이지 288
Managing Server Power
Powering On the Server
If the server was powered off other than through the CIMC, the server will not become active immediately
when powered on. In this case, the server will enter standby mode until the CIMC completes initialization.
Note
If any firmware or BIOS updates are in progress, do not change the server power until those tasks are
complete.
Important
Before You Begin
You must log in with user or admin privileges to perform this task.
Procedure
Purpose
Command or Action
Enters chassis command mode.
Server# scope chassis
Step 1
Turns on the server.
Server /chassis # power on
Step 2
This example turns on the server:
Server#
scope chassis
Server /chassis #
power on
This operation will change the server's power state.
Continue?[y|N]y
Server /chassis #
show
Power Serial Number Product Name
UUID
----- ------------- ------------- ------------------------------------
on
Not Specified Not Specified 208F0100020F000000BEA80000DEAD00
Powering Off the Server
If any firmware or BIOS updates are in progress, do not power off the server until those tasks are complete.
Important
Before You Begin
You must log in with user or admin privileges to perform this task.
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
18
OL-28893-01  
Managing the Server
Managing Server Power