CBX ELECTRICAL CONNECTIONS 
4
4.3  AUXILIARY RS232 INTERFACE 
 
The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave 
connections. When it is connected to the host computer it allows both transmission of code 
data and reader configuration by VisiSet™. 
 
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular 
communication modes such as LOCAL ECHO can be defined through the Communication 
folder of the VisiSet™ utility program. 
 
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for 
device configuration or communication monitoring. 
 
 
5
1
6
9
 
 
Figure 48 - 9-pin female connector 
 
If permanent system wiring is required, the following pins are used to connect the RS232 
auxiliary interface: 
 
CBX100/500 
Function 
RX 
Auxiliary Interface Receive Data 
TX 
Auxiliary Interface Transmit Data 
SGND 
Auxiliary Interface Reference 
 
 
 RX TX 
Reference
USER INTERFACE 
 
Figure 49 - RS232 Auxiliary Interface Connections 
 
 
 
NOTE 
Do not connect the Aux Interface to the CBX spring clamp connectors and 
the 9-pin connector simultaneously. 
 
 