MATRIX-2000™ REFERENCE MANUAL 
 
4.4 INPUTS 
 
There are two optocoupled polarity insensitive inputs available on the reader: Input 1 
(External Trigger) and Input 2, a generic input: 
 
The External Trigger can be used in One Shot Mode or in Phase Mode. Its main functions 
are: 
•  acquisition trigger in One Shot Mode 
•  reading phase-ON/reading phase-OFF command in Phase Mode 
 
The main functions of the general purpose Input 2 are: 
•  second external trigger in Phase Mode 
•  match code storage command when the Match Code option is enabled 
 
The electrical features of both inputs are: 
 
V
AB
 = 30 Vdc max. 
I
IN
 = 10 mA (reader) + 12 mA (CBX) max. 
 
The active state of these inputs are selected in software. 
 
An anti-disturbance filter (debounce filter) is implemented in software on both inputs and is 
software programmable to filter in the range from 500 microseconds to 10 milliseconds. 
 
Refer to the Digital I/O folder in the VisiSet™ Help On Line for further details. 
 
These inputs are optocoupled and can be driven by both NPN and PNP type commands. 
 
 
NOTE 
Polarity insensitive inputs assure full functionality even if pins A and B are 
exchanged. 
 
 
The connections are indicated in the following diagrams: 
 
CBX100/500
 
Function
 
+V 
Power Source - External Trigger 
I1A 
External Trigger A (polarity insensitive) 
I1B 
External Trigger B (polarity insensitive) 
-V 
Power Reference - External Trigger  
 
 
When current flows through the I1A-B input (External Trigger), the yellow TRIG LED (Figure 
A, 6) is on. 
 