Toshiba XLTR-200 사용자 설명서

다운로드
페이지 99
 
  
72
Parameter 
Function / Title 
Bank 
Mask 
Adjustment Range 
Multiplier 
0061 
LOW SPEED SIGNAL 
OUTPUT FREQ 
0 / 1 
FFFF 
∼ Fmax 
0.01 
0062 
ACC/DEC COMPLETE 
DETECT BAND 
0 / 1 
FFFF 
∼ Fmax 
0.01 
0063 
SPEED REACH MAXIMUM 
FREQUENCY 
0 / 1 
FFFF 
∼ Fmax 
0.01 
0064 
SPEED REACH MINIMUM 
FREQUENCY 
0 / 1 
FFFF 
∼ Fmax 
0.01 
0065 
COMMERCIAL POWER/INV 
SWITCHING OUTPUT 
0 / 1 
00C0 
0000: OFF 
(0) 
0040: Auto switch on trip 
(1) 
0080: At COMMERCIAL POWER/ 
INV SWITCH FREQ 
(2) 
00C0: Both (1) and (2) 
(3) 
 
0066 
2, 3 
COMMERCIAL 
POWER/INV 
SWITCH FREQ 
0 / 1 
FFFF 
∼ Fmax 
0.01 
0067 
“FP” OUTPUT TERMINAL 
PULSE FREQUENCY 
0 / 1 
0003 
0000: 48f 
(0) 
0001: 96f 
(1) 
0002: 360f 
(2) 
 
0068 
RR INPUT SPECIAL 
FUNCTION SELECT 
0 / 1 
00E0 
0000: Standard 
(0) 
0040: Fmax 
(1) 
0080: TACC/TDEC multiplier 
(2) 
00C0: VB multiplication factor  (3) 
0020: CL multiplication factor  (4) 
