Toshiba XLTR-200 사용자 설명서

다운로드
페이지 99
 
  
73
Table 9:  Input Terminal Selections 
Setting 
Value 
Data 
(Hex) 
Function 
Setting 
Value 
Data 
(Hex) 
Function 
10C8 
(reverse run) 
28 
04AF 
Binary bit #6 
011C 
SS1 
(preset speed selection) 
29 
08AF 
Binary bit #7 
021C 
SS2 
(preset speed selection) 
30 
10AF 
Binary bit #8 
041C 
SS3 
(preset speed selection) 
31 
20AF 
Binary bit #9 
081C 
SS4 
(preset speed selection) 
32 
40AF 
Binary bit #10 
20C8 
(forward run) 
33 
04CE 
No effect 
201B 
RES 
(fault reset) 
34 
01C7 
UP/DOWN frequency setting (UP) 
C0C9 
ST 
(gate ON/OFF) 
35 
02C7 
UP/DOWN frequency setting 
(DOWN) 
0CC8 
JOG selection 
36 
04C7 
UP/DOWN frequency clear 
081A 
Accel / decel #1/#2 selection 
37 
08C7 
PUSH-type RUN key 
10 
101B 
Emergency off 
38 
10C7 
PUSH-type STOP key 
11 
021B 
DC injection braking ON/OFF 
39 
02B9 
No effect 
12 041B 
Fundamental 
parameter 
switching (V/F #2) 
40 
C0C8 
Forward/reverse run selection 
13 
011B 
Feedback control ON/OFF 
41 
20C7 
RUN 
14 
10CE 
Pattern run selection #1 
42 
30C9 
Binary data write 
15 
20CE 
Pattern run selection #2 
43 
0198 
[LOCAL/REMOTE] key 
16 
40CE 
Pattern run selection #3 
44 
0298 
[MON] key 
17 
80CE 
Pattern run selection #4 
45 
0498 
[PRG] key 
18 
02CE 
Pattern run continue signal 
46 
0898 
[UP] key 
19 
01CE 
Pattern run step trigger signal 
47 
1098 
[DOWN] key 
20 
0AC9 
JOG forward run 
48 
2098 
[READ/WRITE] key 
21 
06C9 
JOG reverse run 
49 
4098 
[RUN] key 
22 
10AE 
Binary bit #0 
50 
8098 
[STOP/CLEAR] key 
23 
20AE 
Binary bit #1 
51 
08CE 
Commercial power / inverter 
switching signal 
24 
40AE 
Binary bit #2 
52 
40C7 
Reserved for option use 
25 
80AE 
Binary bit #3 
53 
10CB 
RR frequency switching input 
26 
01AF 
Binary bit #4 
54 
20CB 
IV frequency switching input 
27 
02AF 
Binary bit #5 
 
 
 
 
Note
In order for binary bit #0 
∼ #10 (setting values 22 ∼ 32) and UP/DOWN frequency setting (setting values 34 & 
35) inputs to be valid, parameter FREQUENCY PRIORITY SELECTION #1 or FREQUENCY PRIORITY 
SELECTION #2 in GROUP:FREQUENCY SETTING PARAMETERS must be set to 5 (BIN (binary setting or 
UP/DOWN setting)).