Toshiba DEV002Z 사용자 설명서

다운로드
페이지 20
E6581295⑥ 
- 15 - 
5.3.  f830: Assembly Object Setting 
The Input/Output Instance of DEV002Z is set up by this parameter. 
The DEV002Z supports both the standard DeviceNet AC Drive profile Instances 20/70, 
21/71 and user defined Instances 100/150, 101/151, 102/152. 
* For an explanation of f830 = 0 (Instance 20/70), 1 (Instance 21/71), 3 (Instance 
101/151) and 4 (Instance 102/152), refer to the function manual (E6581281).   
 
f830
=2 (Instance 100/150)   
Drive Reference Speed
 command value 
A frequency should be specified in hexadecimal notation in units of 0.01Hz.   
For example, to set the frequency at 60Hz, since the minimum unit of frequency is 
0.01Hz, you have to enter the following number.   
60÷0.01 = 6000 = 0x1770 (hexadecimal) 
Byte 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
 
DC 
braking 
Acc./Dec. 
#1/#2 
PI control
Motor 
#1/#2 
Preset 
Speed 4
Preset 
Speed 3 
Preset 
Speed 2 
Preset 
Speed 1
 
 
Command 
link 
Frequency 
link 
Reset 
trip 
Emerg. 
stop 
Free run 
(ST) 
Run/Stop 
Forward/ 
Reverse 
Jog 
Drive Reference Speed Hz (Low byte) 
Drive Reference Speed Hz (High byte) 
Output Instance 100 format 
 
Byte 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
 
DC 
braking 
Acc./Dec. 
#1/#2 
PI control
Motor 
#1/#2 
(Reserved)
ALARM 
(fc91) 
Fault Fault 
FL
(Reserved) 
READY 
without  
ST/RUN 
READY 
with  
ST/ RUN
Emerg. 
stop 
Free run 
(ST) 
Run/Stop 
Forward/ 
Reverse 
Jog 
Drive Actual Speed Hz (Low byte) 
Drive Actual Speed Hz (High byte) 
Input Instance 150 format