- 26 -
Connections
$
Connecting the AC adapter for use with the pan/tilt head
Connect the pan/tilt head with the AW-PS300A AC adapter designed for use with the
pan/tilt head.
pan/tilt head.
Standard bare end length 11 mm
It is recommended that the tip be soldered.
It is recommended that the tip be soldered.
AC adapter for use with the
pan/tilt head: AW-PS300A
pan/tilt head: AW-PS300A
>
DC 12V IN terminal board
Connect this to the DC 15V OUT
connector on the AC adapter
(AW-PS300A). (The voltage output from
the AC adapter is set to 15V: this takes
into consideration the voltage drops due
to the possible extension of the DC
cable between the pan/tilt head and AC
adapter.)
Make sure that the positive
connector on the AC adapter
(AW-PS300A). (The voltage output from
the AC adapter is set to 15V: this takes
into consideration the voltage drops due
to the possible extension of the DC
cable between the pan/tilt head and AC
adapter.)
Make sure that the positive
+
and
negative
-
ends of the wires are
connected to the same signs on the
connector.
Use a cable with a nominal cross
section of 1.25 mm
connector.
Use a cable with a nominal cross
section of 1.25 mm
2
or more that meets
the UL specifications for the connection.
The maximum allowable cable length is
98.4 ft. (30 meters).
The maximum allowable cable length is
98.4 ft. (30 meters).
Applicable (usable) wire
UL Type SPT-2
2
!
16 AWG or
UL Type NISPT-2 2
!
16 AWG
?
LAMP CONTROL terminal board
Connect this only when the power of a
halogen lamp is to be supplied from the
AC adapter (AW-PS300A).
This connector is connected to LAMP
halogen lamp is to be supplied from the
AC adapter (AW-PS300A).
This connector is connected to LAMP
CONTROL on the AC adapter for the
pan/tilt head.
The symbols C and S on the wires must
match the same symbols on the
connector.
Use a cable with a nominal cross
section of 0.3 mm
pan/tilt head.
The symbols C and S on the wires must
match the same symbols on the
connector.
Use a cable with a nominal cross
section of 0.3 mm
2
or more that meets
the UL specifications for the connection.
The maximum allowable cable length is
98.4 ft. (30 meters).
The maximum allowable cable length is
98.4 ft. (30 meters).
@
OP terminal board
Connect this only when the OP SW
CONTROL OUT connector on the AC
adapter (AW-PS300A) is to be used.
Connect it to the OPTION SW
CONTROL IN connector on the AC
adapter (AW-PS300A).
Use a cable with a nominal cross
section of 0.3 mm
CONTROL OUT connector on the AC
adapter (AW-PS300A) is to be used.
Connect it to the OPTION SW
CONTROL IN connector on the AC
adapter (AW-PS300A).
Use a cable with a nominal cross
section of 0.3 mm
2
or more that meets
the UL specifications for the connection.
The maximum allowable cable length is
98.4 ft. (30 meters).
The maximum allowable cable length is
98.4 ft. (30 meters).