Page 41
Property Management System - Communication Interface
Message Formats
Check In/Check Out (Model 60)
These messages do not represent unique features as such, but are a convenient tool 
for activating a sequence of functions commonly performed when a guest checks 
in or out of a room. These messages are exclusively used by the Model 60 with the 
sole exception of Check Out Outgoing Call Report (16-C) which is also used by the 
Model 90 version.
The Feature Codes are as follows:
16-1 -- Check In 1
16-2 -- Check Out
16-5 -- Check Out Message Waiting Lamp Off Report
16-6 -- Check Out Message Waiting Lamp On Report
16-A -- Check In 2
16-B -- Check In 3
16-C -- Check Out Outgoing Call Report
16-D -- Check Out Message Waiting Report
Check In 1
Figure 4-10   Check In 1
The only message field is the extension number who is being checked in. If the 
extension number is less than six digits, left justify the number and fill the 
remaining bytes with space (20H) characters. The Room Status is set to “Stay” and 
Room Cut-Off is cancelled.
‘1’ ‘6’
‘1’
‘1’
‘1’ Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC