This installation procedure assumes that the NIC adapter is 
configured with the correct IP address, subnet mask, and gateway 
(if required). In addition you can also ping and telnet to the NIC 
adapter.
To verify the NIC settings, print an E-net Test Page by doing the 
following:
(P5000, T5000e/SL5000e) DIAGNOSTICS
Printer 
Tests
E-Net Test Page
Enter.
(P7000, T5000r/SL5000r) DIAGNOSTICS
 Printer Tests 
 
Ethernet Test
Enter.
(L55xx, L1524) DIAGNOSTICS
Test Pattern
E-Net Test 
Page
Enter.
The default NIC queue name is d1prn (in lower case), however the 
name can be changed. To verify the queue name, print an E-Net 
Test Page or telnet to the adapter and do a “list dest” command.
AIX Remote Queue Time–Out Setting
Symptoms: Print jobs restart or queue goes down.
If the queue is set up for standard processing (not local filtering), 
add -T50 flag to rembak to the queue device stanza for the queue 
in /etc/qconfig
backend = /usr/lib/lpd/rembak -T50
If the queue was set up for local filtering edit the file 
/usr/lib/lpd/pio/etc/piorlfb and change the line;
typeset piorlfb_rbflags=’’’’
to
typeset priorlfb_rbflags=”-T50”