IBM EM78M611E 사용자 설명서

다운로드
페이지 44
EM78M611E
 
Universal Serial Bus Series Microcontroller
 
 
16 
•••
 
Product Specification (V1.1) 11.22.2006
 
 
(This specification is subject to change without further notice) 
 
RF [2]  USB Suspend interrupt flag.  It will be set when the EM78M611E finds the 
USB Suspend Signal on USB bus.  This bit is cleared by the firmware. 
RF [3]  USB Reset interrupt flag. It will be set when the host issues the USB Reset 
signal.  
RF [4]   P74/P75/P76/P77 Port state change interrupt flag.  
In PS2 Mode, only pins configured as inputs can cause this interrupt to occur. 
These pins (P74, P75, P76 and P77) are compared with the value latched on 
the last read of Port 7. 
In USB Mode, P76 and P77 have this function.  
NOTE 
R F[4]: Port State Change Interrupt Flag, 
EM78M611 
    USB Mode –P76 and P77 DO NOT have interrupt function.  
   PS2 Mode – P74/P75/P76/P77 have interrupt function.  
EM78M611E 
   P74/P75/P76/P77 all have interrupt function (in USB & PS2 mode) 
RF [5, 6] SE1 / SE2 Pattern Detect Interrupt flag. These two flags are used for Pattern 
detect application.  
RF [7]  USB Host Resume interrupt flag. It will be set only in Dual clock mode when 
the USB suspend signal becomes low.  
NOTE 
RF [7]: USB Host Resume_IF 
In EM78M611, this bit is always ‘1’. It is not for use.  
In EM78M611E, this bit is O.K. for use.  
8.2.3  Control Registers 
Some special purpose registers are available for special control purposes.  Except for 
the Accumulator (ACC), these registers must be read and written with special 
instructions.  One of these registers, CONT, can only be read by the instruction 
"CONTR" and written by "CONTW" instruction.  The other special control registers can 
be read by the instruction "IOR" and written by the instruction "IOW". 
The following paragraphs describe only the general functions of the control registers.  
8.2.3.1  A (Accumulator) 
The  accumulator  is  an  8-bit  register  that  holds  operands  and  results  of  arithmetic 
calculations.    It  is  not  addressable.    After  an  interrupt  occurs,  the  Accumulator  is 
auto-saved by hardware.