IBM EM78M611E 사용자 설명서

다운로드
페이지 44
EM78M611E
 
Universal Serial Bus Series Microcontroller
 
 
Product Specification
 
(V1.11) 04.20.2007
 
 
 
•••• 17 
(This specification is subject to change without further notice)
 
 
8.2.3.2  CONT (Control Register)  Default Value: (0B_0011_1111) 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
LED  
INT 
TSR2 
TSR1 
TSR0 
PSR2 
PSR1 
PSR0 
Except for Bit 6 (Interrupt enable control bit), the CONT register can be read by the 
instruction "CONTR" and written by the instruction “CONTW". 
CONT [0~2]  Watchdog Timer prescaler bits.  These three bits are used as the 
Watchdog Timer prescaler.  
CONT [3~5]   TCC Timer prescaler bits.   
The relationship between the prescaler value and these bits are shown below: 
PSR2/TSR2 
PSR1/TSR1 
PSR0/TSR0 
TCC Rate 
WDT Rate 
1: 2 
1: 1 
1: 4 
1: 2 
1: 8 
1: 4 
1: 16 
1: 8 
1: 32 
1: 16 
1: 64 
1: 32 
1: 128 
1: 64 
1: 256 
1: 128 
 
NOTE 
WDT Timing base is “Power-on time”.  Set by the code option [2, 1.] 
Ex. Code option [2 ,1] = 01 (2ms), and Prescaler = 1:128.  
 
WDT overflow time is:  2mS * 2^7 = 256 mS 
CONT [6]   Interrupt  enable  control  bit.  This  bit  toggles  Interrupt  function  between 
enable and disable.  It is set to 1 by the interrupt disable instruction "DISI" 
and reset by the interrupt enable instructions "ENI" or "RETI." 
 
0
 : Disable the Interrupt function 
 
1
 : Enable the Interrupt function 
CONT [7]    LED bit.  This bit is used to enable the LED sink capacity of P76 and P77.  
 
0
 : Disable the LED sink capacity of P76, P77 
 
1
 : Enable the LED sink capacity of P76, P77