Intel SRCSATAWB 사용자 설명서

다운로드
페이지 34
7
Intel® RAID Controller SRCSATAWB Hardware User’s Guide
Figure 2. Installing the Intel
®
 RAID Controller SRCSATAWB
5. For the first four drives, ports 0 - 3, connect one 4-port combined end of an internal 
cables to the upper connector. If you are using more than four drives without using 
an expander backplane, connect the second cable to the lower connector. See the 
following figure.
Notes:
To prevent throughput problems, use the cables provided or use the shortest possible 
cable. Do not use cables longer than one meter. Decrease the maximum length by 
one foot if using a backplane. 
Do not use cross-over cables. 
The cables are labeled with the word “SAS,” but only SATA drives are supported. 
Do not attempt to install a SAS drive. Only connect to a SATA drive or to a 
SAS/SATA backplane. The RAID Controller SRCSATAWB uses an advanced 
software stack that allows connections to SATA drives either directly or via SAS or 
SATA backplanes with or without expanders.
Route the cables carefully. Check that controller and cables are all properly 
attached.