6.2  Alarm Text Files
ETERNUSmgr User Guide -Introduction-    P2X0-0202-01EN
The "alarm history messages" shown above indicate the status results obtained from the target device.
The following message is output when all components of the target device are normal.
If target device monitoring does not work properly (due to LAN drop-out, failure on the network path, or
incorrect target address setting, etc.), and the Detect Offline Targets parameter has been set, the following
message will be output.
See 
, "Hardware Status was changed. See below ..." for details of the mes-
sages displayed in the alarm history file.
Note that "Hardware Status was changed. See below ..." is not an actual alarm history message.
6.2
Alarm Text Files
This section explains the alarm text files that are generated by ETERNUSmgr.
Alarm text files are a compilation of the alarm history messages for a single day in a text format. See 
 for more information on the alarm history messages.
Alarm text files are categorized into the following types:
• Alarm Text Date Files
Contains the individual alarm history messages that record the ongoing status of the tar-
get device, collected on a day-by-day basis.
• Alarm Text Fixed File
Contains the same alarm history messages as the latest alarm text date file, saved under 
a settable name.
Alarm Text Date Files
The alarm text date file is saved in the directory specified in the setup file using the following file naming
convention. See 
 for more information about the setup files.
YYYY
: Year
MM
: Month
DD
: Day
For example, "stxgr20030101.log" indicates an alarm text date file that was created on January 1, 2003.
Alarm text date files are created/updated when an alarm history file is created. Alarm text date files are cre-
ated/updated when an alarm history file is created.
"No hardware error detected."
"No hardware report detected. (Offline)"
Date:1/1/2003
ETERNUS3000 Address:10.20.30.40
ControllerEnclosure#0001:ALARM
ControllerEnclosure#0002:BTU-CAUTION
ControllerEnclosure#0003:ALARM&BTU-CAUTION
DriveEnclosure#0003:ALARM
ETERNUSmgr(stxpoll) V20L20
ETERNUS3000 Hardware Status List
Header
(title, date, address of the target device)
Alarm List
Footer
(ETERNUSmgr Version)
stxgrYYYYMMDD.log