3. Installation Procedures
RuggedCom® RuggedMAX WiN7000
25
Installation Guide Rev1
3.6.2. SFD Type Base Station
The power system is supplied by the operator.
Connect  the  power  system  DC  output  to  the  RuggedCom  cable  with  proprietary  connector
(supplied by RuggedCom).
Connect  the  other  side  (open  end)  of  the  RuggedCom  cable  to  the  operator’s  power  system
(according to the labelling on the cable and the tables below.
RuggedCom Cable
Power Supply
Note
-48VDC
-48VDC
GND
+48VDC
+48VDC/ GND
“HOT Line”
GND
-48VDC/ GND
Connect -48V and GND
Table 3.4. +48 VDC Power System
RuggedCom Cable
Power Supply
Note
-48VDC
-48VDC
“HOT Line”
+48VDC
+48VDC/ GND
GND
GND
+48VDC/ GND
Connect +48V and GND
Table 3.5. -48 VDC Power System
  and 
  show
+48V and -48V configurations.
Figure 3.11. Positive 48V Configuration
Figure 3.12. Negative 48V Configuration