Transition Networks                                                                                                                  MIL-SM2401MAF 
 
24-Hour Technical Support: 1-800-260-1312                                                  International: 00-1-952-941-7600 
                                                                               
 
95
 
power classification function. 
  Power Limit by Management: Tick this check box to enable/disable the port 
power limit management for PoE power management. 
  Detect Legacy Signature: By default, the PoE switch only provides power to 
the  connected  PD  which  follows  the  IEEE  802.3af  standard.  Having  ticked 
this check box, the legacy detection is to identify the PD (not in compliance 
with the IEEE 802.3af standard) their unique electrical signatures in order for 
the PoE switch can provide the power to the PD. 
  Priority: Set port priority for the PoE power management. 1 = C (critical), 2 = 
H (High), 3 = L (Low). 
  Power Limit Max (mW) (<15400): Set the power limit value. The maximum 
value must less 15400mW. 
  Fault Status: The PD error status message. 
  Null: It means no PD is connected or the connected PD status is normal. 
  Overload:  It  means  the  current  is  over  the  PD  current  classification 
limited (475mA @ 48V DC) over 50ms. 
  Mode Status: The PD current operation mode status. 
  V  sample  or  I  sample:  It  means  Current  sample  or  Voltage  sample.   
When PD  is  detected and  current  is  supplied, the  PoE  switch  will  keep 
detecting  and  sampling  some  current  or  voltage  to  ensure  whether  the 
PD is still active on the port. It is an IEEE 802.3af operating procedure. 
  R detect: When the port doesn’t connect with any PD, the PoE switch 
will poll each port and detects the resistor. 
  Discovery R (ohms): Displays the resistance value. 
  Port Current (mA): Displays the current value. 
  Port Voltage (V): Displays the voltage value. 
  Port Power (W): Displays the watt value. 
  Class Current (mA): Displays current class. When the Bypass classification 
is enabled, the class value will not show in here. 
  Determined Class: Displays power class. When the Bypass classification is 
enabled, the class value will not show in here.