Transition Networks MIL-SM2401MAF 사용자 설명서

다운로드
페이지 111
Transition Networks                                                                                                                  MIL-SM2401MAF 
 
24-Hour Technical Support: 1-800-260-1312                                                  International: 00-1-952-941-7600 
                                                                               
 
96
 
Troubleshooting 
 
 
This section is intended to help solve the most common problems on the 24 10/100TX 
plus 2 Mini-GBIC/Copper managed PoE switch. 
 
Incorrect connections 
 
The  switch  port  can  automatically  detect  straight  or  crossover  cable  when  the  user 
links the switch with other Ethernet device. For the RJ-45 connector should use correct 
UTP or STP cable, 10/100Mbps ports use 2 pairs twisted cable. If the RJ-45 connector 
is not correctly pinned on right position, the link will fail. For fiber connection, please 
notice that fiber cable mode and fiber module should be match. 
 
  Faulty or loose cables 
 
Look for loose or obviously faulty connections. If they appear to be OK, make sure the 
connections are snug. IF that does not correct the problem, try a different cable. 
 
  Non-standard cables 
 
Non-standard  and  miss-wired  cables  may  cause  numerous  network  collisions  and 
other network problem, and can seriously impair network performance. A category 5 
cable tester is a recommended tool for every 100Base-T network installation. 
 
RJ-45  ports: 
use  unshielded  twisted-pair  (UTP)  or  shielded  twisted-pair  (STP) 
cable  for  RJ-45  connections:  100Ω  Category  3,  4  or  5  cable  for  10Mbps 
connections,  100Ω  Category  5  cable  for  100Mbps  connections,  or  100Ω 
Category 5e/6 cable for 1000Mbps connections. Also be sure that the length of 
any twisted-pair connection does not exceed 100 meters (328 feet).