Installing and Cabling the Cabinets
106 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Reset LEDs on Power Distribution Unit
A red LED next to any of the 32 power output connectors indicates a short circuit in the building 
wiring or the terminal equipment. To reset the LED:
1. Disconnect the terminal equipment from the wall jack.
2. If the LED goes off, the terminal equipment is faulty and must be replaced. If the LED is still 
lit, find and repair the short circuit in the building wiring.
3. Reconnect the terminal equipment to the wall jack and retest terminal equipment operation.
1152A1 Mid-Span Power Distribution Unit
The 1152A1 Mid-Span Power Distribution Unit (PDU) is an Ethernet power supply that provides 
power to up to 24 46xx-series IP telephones or wireless LAN (WLAN) access points. This unit is 
used with a 10/100BaseTx standard Ethernet network over a standard TIA/EIA-568 Category 5, 
6 or 6e cabling plant. The 1152A1 meets the current requirements of the IEEE802.3af standard 
for resistive detection.
The 1152A1 PDU complies with the Underwriters Laboratories Inc. (UL) standard UL 1950, 
second edition.
For safety instructions, see 
on page 106. For installation 
instructions, see 
Important Safety Instructions
Please read the following helpful tips. Retain these tips for later use. 
When using this switch, the following safety precautions should always be followed to reduce 
the risk of fire, electric shock, and injury to persons.
Read and understand all instructions.
Follow all warnings and instructions marked on this switch.
Table 16: 1152A1 PDU UL 1950 Compliance
Complies
UL 1950
Approved
CSA C22.2 No.950 Std.
Approved
CE Regulatory 
Compliance
Approved
EN 60950
Approved
TUV EN 60950