Installing and Cabling the Cabinets
116 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Alarm Output
The system provides a relay contact that can operate a customer-provided alarm, such as a 
light or bell. The circuitry and power source are customer- provided. The alarm device must not 
exceed a rating of more than 30 VAC RMS or 60 VDC at 0.75 Amps. 
1. Connect the external alarm output. See 
2. Give this information to your Avaya representative for troubleshooting purposes.
Emergency Transfer and Auxiliary Power
Note:
Note:
Only 1 emergency transfer power panel and 1 auxiliary power connection is 
provided per system.
Connect emergency transfer power and auxiliary power as shown in 
. Auxiliary power 
includes power to an attendant console or adjunct device. 
Table 20: Alarm Output at AUX Connector
Alarm Output 
Type
Color
AUX Connector
EXTALMA
Violet-Green
(Pin 48)
EXTALMB
Green-Violet
Ground (Pin 23)
Table 21: Emergency Transfer and Auxiliary Power
Power Type
Color
AUX Connector
Emergency Transfer
Black-Blue 
XFER48 (Pin 36)
Blue-Black
Ground (Pin 11)
 Auxiliary (Adjunct) -48 VDC
Brown-Yellow
ACC48A (Pin 19)
Yellow-Brown
Ground (Pin 44)