Avaya CMC1 사용자 설명서
![Avaya](https://files.manualsbrain.com/attachments/539de53b12b0cfce0bb8cf1e3bb961e969d9f556/common/fit/150/50/0bfb423b07b431ecf5ac095ccde7771f5eac50e962dfba59f8e256280b3d/brand_logo.png)
Completing Installation and Cable Pinouts
158 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
TN760E Tie Trunk Option Settings
The TN760E Tie Trunk circuit pack interfaces between 4 tie trunks and the TDM bus. Two tip
and ring pairs form a 4-wire analog transmission line. An E and M pair are DC signaling leads
used for call setup. The E-lead receives signals from the tie trunk and the M-lead transmits
signals to the tie trunk.
and ring pairs form a 4-wire analog transmission line. An E and M pair are DC signaling leads
used for call setup. The E-lead receives signals from the tie trunk and the M-lead transmits
signals to the tie trunk.
To choose the preferred signaling format (
), set the switches on the
TN760E and administer the port using
Table 31: Signaling Formats for TN760E
Mode
Type
E & M
Type I Standard (unprotected)
E & M
Type I Compatible (unprotected)
Protecte
d
d
Type I Compatible, Type I
Standard
Standard
Simplex
Type V
E & M
Type V
E & M
Type V Revised
Table 32: Signaling Type Summary
Signaling Type
Transmit (M-Lead)
Receive (E-Lead)
On-Hook
Off-Hook
On-Hook
Off-Hook
Type I Standard
ground
battery
open
1
/battery
1. An open circuit is preferred instead of battery voltage.
ground
Type I Compatible
open
1
/battery
ground
ground
open
1
/
battery
Type V
open
1
/battery
ground
open
ground
Type V Reversed
ground
open
ground
open