Upgrading R6csi/R7csi/R8csi to Avaya Communication Manager on an Avaya DEFINITY Server CSI
192 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Save Announcements (if necessary)
Note:
Note:
The TN750C and TN2501AP Integrated Announcement circuit packs store 
announcements in nonvolatile memory; saving the announcements to a flashcard 
is optional.
To save announcements:
1. If the PPN contains a TN750/B Announcement circuit pack, type display announcements 
and press Enter.
2. If administered recorded announcements are listed, type save announcements UUCSS 
and press Enter. For example, 01D03. This takes about 30 minutes.
Note:
Note:
For some DEFINITY ECS software versions, type save announcements from 
UUCSS. Type help and press Enter for complete command syntax.
Shut Down DEFINITY AUDIX System (if necessary)
!
WARNING:
WARNING:
Neglecting to shut down the AUDIX assembly before powering down the system 
cabinet where it resides can damage the AUDIX disk.
To shut down the DEFINITY AUDIX system:
1. Shut down the AUDIX assembly and allow the disk to completely spin down. Refer to 
!
CAUTION:
CAUTION:
If leaving AUDIX System in the carrier, back it out about 2 in. (5 cm) to eliminate 
the possibility of damage due to power surges.
Replace Circuit Packs
!
CAUTION:
CAUTION:
When working with any cabinet hardware, wear a grounded wrist strap to ground 
yourself against electrostatic discharge (ESD).
To replace circuit packs:
1. Pull out the TN798 processor to power down the cabinet.