Avaya CMC1 사용자 설명서

다운로드
페이지 370
Add DS1 Tie and OPS
Issue 10 June 2005
255
 
Add DS1 Tie and OPS
The TN2313AP DS1 Tie Trunk and TN767B (or later) DS1 Interface circuit packs provide 
connections to a 1.544 Mbps DS1 facility (T1) as 24 independent 
64 Kbps trunks. 
The TN2313AP DS1 Tie Trunk, TN767B (or later) DS1 Interface, and TN464HP DS1 Interface 
circuit packs provide connections to a 2.048 Mbps DS1 facility (E1) as 32 independent 64-kbps 
trunks.
Service Interruption
To add DS1 tie and OPS trunks:
1. Since the addition of DS1 tie-trunk service may require a service interruption, notify the 
customer in advance as to when the addition will occur.
2. For information about administering DS1 Tie Trunks, refer to Administrator’s Guide for 
Avaya Communication Manager.
Table 55: Tie Trunk Option-Switch Settings and Administration 
Installation Situation
Preferred Signaling 
Format
E&M/SMPLX
Switch
Prot/Unprot
Switch
Administered
Port
Circumstance
To
System
Far-End
Collocated
Avaya 
CMC1 
Media 
Gateway
E&M Type 
1
E&M Type 
1
E&M
Unprotected
Type 1
Compatible
Standard
Compatible
Inter-Building
Avaya 
CMC1 
Media 
Gateway
Protected 
Type 1
Protected 
Type 1
E&M
Protected
Type 1
Compatible
Standard 
Plus
Compatible
Protection
Unit
Collocated
Net 
Integrated
E&M Type 
1
Any PBX
E&M
Unprotected
Type 1
Standard