Avaya CMC1 사용자 설명서
Adding or Removing Hardware
266 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
add data-module
To administer the data module that is associated with the TN2501AP ethernet port.
1. At the SAT, type add data-module extension/next and press RETURN.
The Data Module screen appears.
Figure 89: Data Module screen (add data-module extension)
2. Set the
Type
field to ethernet.
3. Set the
Port
field to correspond to the circuit pack location.
In the example above, 1b0333 means Cabinet 1, Carrier B, Slot 3, Port 33.
Note:
Note:
The port number (final two digits) is always 33 for the TN2501AP circuit pack.
4. Set the
Link
field to an unassigned or next-available link number.
5. Set the
Network uses 1’s for Broadcast Address?
field according to the your
network requirements.
6. Type a unique name in the
Name
field.
7. Press ENTER to save your changes.
8. If your system uses IP routing, continue with the
section.
9. Otherwise, go to the
section.
add ip-route
Use the
add ip-route
command to administer IP routes to the TN2501AP circuit pack. This
administration is optional.
add data-module 30006 Page 1 of 1 SPE A
DATA MODULE
Data Extension: 30006 Name: VAL#2 Data Module
Type: ethernet
Port: 1b0333
Link: 5
Network uses 1’s for Broadcast Addresses? y