Adding or Removing Hardware
266 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
add data-module
To administer the data module that is associated with the TN2501AP ethernet port.
1. At the SAT, type add data-module extension/next and press RETURN.
The Data Module screen appears.
Figure 89: Data Module screen (add data-module extension)
2. Set the 
Type
 field to ethernet.
3. Set the 
Port
 field to correspond to the circuit pack location.
In the example above, 1b0333 means Cabinet 1, Carrier B, Slot 3, Port 33.
Note:
Note:
The port number (final two digits) is always 33 for the TN2501AP circuit pack.
4. Set the 
Link
 field to an unassigned or next-available link number. 
5. Set the 
Network uses 1’s for Broadcast Address?
 field according to the your 
network requirements.
6. Type a unique name in the 
Name
 field.
7. Press ENTER to save your changes.
8. If your system uses IP routing, continue with the 
 section.
9. Otherwise, go to the 
 section.
add ip-route
Use the 
add ip-route
 command to administer IP routes to the TN2501AP circuit pack. This 
administration is optional.
add data-module 30006                                    Page   1 of   1   SPE A
                               DATA MODULE
  Data Extension: 30006           Name: VAL#2 Data Module
            Type: ethernet
            Port: 1b0333
            Link: 5
Network uses 1’s for Broadcast Addresses? y