Add Packet Bus Support
Issue 10 June 2005
269
 
Add Packet Bus Support 
Disable Alarm Origination
To disable alarm origination:
1. Type change system-parameters maintenance and press Enter
2. Set the 
Alarm Origination Activated
 field to n.
!
CAUTION:
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, 
resulting in unnecessary trouble tickets. 
3. For some DEFINITY ECS software versions, disable 
Cleared Alarm Notification
 
and 
Restart Notification
 before submitting the form.
Save Translations
Type save translation and press Enter. This instructs the system to take all translation 
information in memory and write it to the translation card.
Install Circuit Packs
Install the appropriate TN circuit packs. See 
.
Table 56: Circuit Pack Locations for Packet Bus in PPN
Circuit Pack
Carrier
Quantity
Slot
TN799DP
Any
1
Any Available Port Slot