Add Packet Bus Support
Issue 10 June 2005
269
Add Packet Bus Support
Disable Alarm Origination
To disable alarm origination:
1. Type change system-parameters maintenance and press Enter.
2. Set the
Alarm Origination Activated
field to n.
!
CAUTION:
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms,
resulting in unnecessary trouble tickets.
resulting in unnecessary trouble tickets.
3. For some DEFINITY ECS software versions, disable
Cleared Alarm Notification
and
Restart Notification
before submitting the form.
Save Translations
Type save translation and press Enter. This instructs the system to take all translation
information in memory and write it to the translation card.
information in memory and write it to the translation card.
Install Circuit Packs
Install the appropriate TN circuit packs. See
.
Table 56: Circuit Pack Locations for Packet Bus in PPN
Circuit Pack
Carrier
Quantity
Slot
TN799DP
Any
1
Any Available Port Slot