Avaya CMC1 사용자 설명서

다운로드
페이지 370
Adding or Removing Hardware
322 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
7. Set the Signaling Mode
:
 field to isdn-pri
8. Set the Connect
:
 field to pbx
9. Set the Interface
:
 field to network
10. Set the Country Protocol
:field
 to 1
11. Set the Protocol Version
:
field to a
12. Set the CRC?
:
field to y
13. The Idle Code default is 11111111.
14. The DCP/Analog Bearer Capability default is 3.1 kHz.
15. Set the MMI Cabling Board
field to
 xxxxx
 (where 
xxxxx
 is the location of the TN787F/
H/J/K MMI circuit pack recorded in step 2). This must be the slot for port B of the Y-cable.
16.
The 
MMI Interface
: field 
ESM appears.
17. Enter 
add signaling-group next
 and the signaling-group form appears.
18. Change Associated Signaling: field to y
.
19. Change 
P
rimary D-Channel Port: field to 
xxxx
17 (where 
xxxx
 is the address of the 
TN2207 PRI circuit pack, for example: 1B0517).
20. The 
M
ax Number of NCA TSC: default is 0
.
21. The Max Number of GA TSC: default is 0
.
22. Trunk Group for NCA TSC: ____ (leave blank)
23. Trunk Group for Channel Selection:____ (leave blank)
24. Logoff the terminal and then log back on the terminal to view your changes.
Place test call
Place multimedia data-conference call to an endpoint with known video capability to test the 
esm function.
Troubleshooting
To determine ESM link status enter the following commands from the system administration 
terminal:
1.Status esm
2.Status signaling-group
3.List MMI