Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn over the projector and remove the air filters by
pulling the latches upward.
1
2
Air filters prevent dust from accumulating on the surface of the optical elements inside the projector. Should the
air filters become clogged with dust particles, they will reduce cooling fans’ effectiveness and may result in a
buildup of internal heat and adversely affect the life of the projector. Clean the air filters by following the steps
below.
Clean the air filters with a brush or rinse them softly.
When rinsing the air filters, dry them well.
3
Replace the air filters properly. Make sure that the air
filters are fully inserted.
4
CAUTION
Do not operate the projector with the air filters
removed. Dust may accumulate on the optical
elements degrading picture quality. Do not put
anything into the air intake vents. Otherwise it may
result in malfunction of the projector.
RECOMMENDATION
We recommend avoidin� dusty/smoky environments 
when you operate the projector. Usa�e in these 
environments may cause poor ima�e quality.
When you use the projector under dusty or smoky
conditions, dust may accumulate on the lens, LCD panels,
or optical elements inside the projector degrading the
quality of a projected image.
When the symptoms above are noticed, contact your
authorized dealer or service station for proper cleaning.
Note:
When reinserting the air filters, be sure that 
the slit part is facing the outer side.
Cleanin� the Air Filters
Maintenance and Cleanin�
Be sure to reset the Filter counter after cleaning or replacing the filters.
Press  the  MENU  button  to  display  the  On-Screen
Menu.  Use  the  Point
◄►
 buttons  to  move  the  red
frame pointer to the Setting Menu icon.
Use  the  Point
▲▼
 buttons  to  move  the  red  frame
pointer  to  Filter  counter  and  then  press  the  SELECT
button.  A  dialog  box  appears  showing  the  total
accumulated  time  of  the  filter  use,  a  timer  setting
option,  and  the  reset  option.  Select  Reset  and  the
“Filter  counter  Reset?”  appears.  Select  [Yes]  to
continue.
1
Resettin� the Filter Counter
Filter counter
Another  confirmation  dialog  box  appears,  select  [Yes]
to reset the Filter counter.
Air filters
Pull up and remove.
Select Reset and
the “Filter counter
Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again
to reset the Filter
counter.