 Troubleshooting - 79
Lamp Indicator
Temperature Indicator
Extinguished
The power is not 
switched on
The power is not switched on.
· Check to ensure that the lamp or fan are 
correctly attached if the lamp has been 
replaced. If the lamp or fan are not correctly 
attached, the projector will assume the same 
status as if the power has not been switched 
on.
· Check the power cord connection.
Check the power supply to the socket.
39
Indicator Status
Cause
Recovery and Status
Reference 
Page
Blinking in Red
Lamp error
· Replace with a new lamp (ELPLP11).
· If the lamp is broken, take care to avoid injury 
and contact your nearest adress provided at 
page 104 to request repairs (images cannot be 
projected unless the lamp is replaced).
91
Blinking in 
Orange
Nearing the time 
for replacing the 
lamp
Prepare a new lamp. It is recommended that 
the lamp is replaced as soon as possible, as 
there are cases where the time for replacement 
is earlier than stated in the conditions of usage.
91
Extinguished
(Not an error)
The power has not been switched on or nor-
mal projection is in progress.
Indicator Status
Cause
Recovery and Status
Reference 
Page
Illuminated in 
Red
Excesive internal 
temperature
(overheating)
· Use the projector within the permissible 
temperature range of between 5 degrees 
Celsius and 40 degrees Celsius.
· Install the projector in a well-ventilated place 
and ensure that the ventilation inlet and 
outlet are not blocked.
22
· Clean the Air Filter.
· Switch the lamp off when the red lamp is 
illuminated to reduce the temperature inside 
the projector.
89
Blinking in Red
Internal error
Cease operations, remove the Power Plug 
from the socket and contact your dealer or 
nearest adress provided at page 104 and 
request repairs.
Indicator Status
Cause
Recovery or Status
Reference 
Page