Disassembly & Assembly
Disassembly Flow
152
4.2.3.21  Removing the Release Sensor/P_THICK Sensor
Right:
Release Sensor that detects the paper hold sensor condition (set or 
released).
Left:
P_THICK Sensor that detects paper thickness (normal or thick)
1.
Remove the R Side Cover as described in “R Side Cover Removal” on 
page 114.
2.
3.
Remove the I/C Holder Cover as described in “I/C Holder Cover Removal” 
on page 116.
4.
5.
Push the paper hold lever down to the rear.
6.
Remove the one (CUPS M3x6) screw securing the sensor bracket and 
remove the bracket along with the both sensors.
NOTE: Sensor bracket position is adjusted at factory. Therefore, be 
sure to mark its current position before removing the screw.
7.
Remove the harness from the connector of the Release/P_THICK Sensor.
8.
Unhook the sensor from the sensor bracket and remove the sensor.
Figure 4-78.  Removing the Release Sensor/P_THICK Sensor
A D J U S T M E N T
R E Q U I R E D
If you move the sensor bracket position, perform the necessary 
adjustment listed in Table 5-2, “Service Parts & Required 
Adjustments,” on page 158.
P_THICK 
Sensor
Detection 
flag
Release 
Sensor
Connector
Connector
Sensor 
Bracket
Screw 
(M3x6)
Hooks
Sensor